1 How to light the pilot on your gas log set - general instructions Featured

Pilot lighting instructions are in your installation instructions that came with the lighting control. They can also be downloaded from www.RasBox.com, specifically at http://rasmussen.host4kb.com/category/51/0/10/Installation-Manuals/ In a nutshell: Ensure…

2 "Easy" Safety Pilot Control System - What is it?

Our “EASY” Safety Control Systems provide convenient lighting and safety shutdown in the event of a gas interruption or flameout. The three main categories use a common valve body, which allows for conversion at a later time from one type to another.…

3 Can the RE-UP1 be used with a Millivolt Valve?

Question: Can the RE-UP1 be used with a Millivolt Valve? Answer: The RE-UP1 is used to convert our EASY Manual Control Valve (SPK3E or ME systems) to Variable flame height remote control. The EASY systems are only for installation on the side of the burner…

4 Can the VEI or EI with Remote control be turned on when the power is out?

Q - Can the VEI (vented) or EI (vent-free) with Remote control be turned on when the power is out? A - Yes. The VEI and EI are powered by 4 AA batteries. We have an accessory (item #GV60-AC) that allows the VEI/EI systems to be powered by your house current.…

5 Can your manual safety pilot be used outside in an environment that reaches -20 degrees F?

The manufacturer’s specified operating temperature range for the valves used in the SPK3E, RMC1E and RPK3E is 0ºF to 225 ºF. The biggest issue I would expect from an outdoors installation, regardless of temperature, would be from the pilot blowing out…

6 Can't turn off Safety Control Valve

Issue: Unable to turn the Safety Control Valve to OFF, so I must use the log lighter valve upstream of the fireplace to turn the pilot off. Fix: With the knob at the PILOT position, slightly depress the knob and turn to the right (clockwise) to turn the knob…

7 Flame out of Air Mixer Holes on Vented Pan Burner

Here are the potential causes of a flame coming out of the air mixer holes: 1) The pan is filled with sand, which creates too much back pressure for the gas to push through the sand, so it takes the path of least resistance by exiting out the air mixer holes.…

8 Gas log safety pilot kit will not light

Q: My gas log safety pilot kit will not light. What should I check? A: Be sure that the inlet and outlet are connected in the correct locations. Remove the heat shield for the gas valve and verify per the arrows on the valve. Inlet (Arrow pointing into the…

9 How to program multiple remote units at one installation.

Q: How do I program two or more remote systems to work in the same space? A: 1. Clear all the codes from the control module or remote receiver. Slide the REMOTE/OFF switch on the control module or remote receiver to the OFF position on all units except the…

10 Match Lighting a Natural Gas Set

To light a “match-lighted” set (no standing pilot safety control installed): 1) Ensure the damper and glass doors are wide open. 2) Light a match or Aim-N-Flame. 3) Place it on the burner pan on the side from which the gas enters the burner (usually the…