1 BTU Ratings for Custom Pan ( CS ) Burners

BTU/hour ratings for Custom Pan Burners (CS). Match Lighted / EIS Ready (-N) Natural (-P) Propane CS16-B- 65k 27k CS18-B- 75k 27k CS21-B- 76k 35k CS24-B- 90k 37k CS27W-B- 100k 60k CS30-B- 110k 50k CS30W-B- 130k 70k CS33W-B- 120k 75k CS36-B- 125k 85k CS42-B-…

2 Convert Vented Gas Log Set to Vent-Free?

Q: I have a vented Rasmussen gas log set. Since much of the heat goes up the chimney, i would like to convert to a ventless log set. Since i already have the logs and various cosmetic pieces, is there a conversion kit to convert to a ventless system from…

3 Custom Embers Pan Burner ( CXF ) Specifications and Dimensions

Custom Embers Burner The Custom Embers Burner is a tapered wedge shaped burner that brings the front of the pan (and embers and flame) to the hearth level. It can be installed flush on the firebox floor, or elevated at the rear using the supplied rear height…

4 Custom Pan Burner ( CS ) Specifications and Dimensions

Custom Pan Burner The Custom Pan Burner is a rectangular pan burner which can be installed on legs or flush on the floor, using volcanic ash poured around the burner to create a pit look. The pan is filled with either Sand (Natural Gas only) or Volcanic Ash…

5 Flame Not Evenly Distributed In Sand Pan Burner - High On One Side

Q: I have a Pan Burner and the flame seems to be in the back and right hand only. How can I get the flame evenly distributed? A: A couple of actions for you to take: 1) Ensure that the sand completely engulfs the burner pipe and underneath the baffle plate…

6 Flame out of Air Mixer Holes on Vented Pan Burner

Here are the potential causes of a flame coming out of the air mixer holes: 1) The pan is filled with sand, which creates too much back pressure for the gas to push through the sand, so it takes the path of least resistance by exiting out the air mixer holes.…

7 Grate with CS Burner?

Q - Can I use a Grate with a CS Burner? A - No. The CS burner does not include, nor is it intended to be used with, a grate. The front and rear logs sit directly on the sand that fills the burner pan. With our F, FX and LC burners the flames are directed…

8 Grate with CXF Burner?

Q - Can I use a Grate with a CXF Burner? A - No. The CXF burner does not include, nor is it intended to be used with, a grate. The front and rear logs sit directly on the sand that fills the burner pan. With our F, FX and LC burners the flames are directed…

9 LC versus LD Multi-Burners

What is the difference between the LC and LD Multi-Burners? - Both burners feature a front burner for embers and a top burner for main flame. The effect is a very full appearance for larger scale fireplaces. - Both have 5/8" grates welded on the diamond,…

10 Match Lighting a Natural Gas Set

To light a “match-lighted” set (no standing pilot safety control installed): 1) Ensure the damper and glass doors are wide open. 2) Light a match or Aim-N-Flame. 3) Place it on the burner pan on the side from which the gas enters the burner (usually the…